Search

Direct Order:

Vocational Training
Automotive Technology
Product groups
Tools
By topic
Automotive Technology
 
CAN fault switch box for CAN comfort
Order-№: 74732Price: in EUR
All prices are
plus delivery charges.
Delivery charges-Info
Net price: 489,00 EUR
Gross price: 581,91 EUR
Add to cart.
 

During the data communication over CAN bus systems it can come to DIN to altogether 8 errors. These CAN errors result alone from errors in the two data lines. Couches errors only in one of the two lines forwards, switch the controllers to single-wire enterprise, the transmission of the signals remain secured, however the line becomes sensitive in relation to electromagnetic spurious signals. Errors in the CAN lines are to be noticed toward outside only if both lines are disturbed, because then the controllers concerned can react not more and fail systems, because relevant data cannot be missing to them or pass them on their data. The single-wire enterprise is put down into error memory of the controllers concerned as error. A possibility of the fault-tracing is measuring by an oscilloscope of the disturbed data lines. Ever after error different patterns indicating defects result for CAN h and CAN l. With the help of the CAN error box eight DIN errors on the CAN lines can be simulated. The error box possesses eight switches, which are numbered of 1-8. The pupils must by the diagnosis with the oscilloscope and the comparison with patterns indicating defects (e.g. self study program NR. 269 "Data exchange on the CAN data bus") finds out, which errors it concerns. Will simply put the CAN error box with their patch cord into a card location of the CAN function box, into the plug connector at the box can a further construction unit be attached, so that through the error box no card location is lost to the CAN function box.

Error switch    Type of error

  1. Exchange CAN-High and CAN-Low
  2. Short-circuit CAN-Low to ground
  3. Short-circuit CAN-High to ground
  4. Interruption CAN-High and CAN-Low
  5. Short-circuit CAN-Low to plus
  6. Short-circuit CAN-High to plus
  7. Interruption CAN-Low
  8. Interruption CAN-High

The box is connected in series with an interface on the CAN function box. Using the switches the following faults can be switched on CAN-H and CAN-L:

  • Open-circuits
  • Short-circuit to positive
  • Short-circuit to earth
  • Reversal
  • Resistances to positive

The signals can be tapped on the control unit side or wiring harness side.